PHYSIOLOGICAL PRESSURE MONITORING > Disposable Pressure Transducer

GENERIC NAME BRAND USES
Disposable Pressure Transducer ACCU+ Polyethylene For accurate measurement of physiological pressure & other important hemodynamic parameters.


FEATURES BENEFITS
Modern mems chip technology Accurate transmission of pressure waves
Transparent housing For easy detection of air bubbles and quick priming
Automatic continuous flow @
3 cc/hr or 30 cc/hr
Maintains catheter patency and eliminates the need for intermittent     manual flushing.
Facilitates dynamic response testing of the monitoring system, allowing     rapid flushing of Pressure Monitoring Line after collection of blood sample.
Assembled & individually tested with automated machines. High quality, safety and reliability of each unit.
Multiple cable end options Compatible with most of the commonly used patient monitors.

MATERIAL SPECIFICATIONS Body & end adaptors Polycarbonate
Polycarbonate Silicone
Capillary flow system Glass
Luer Caps Polyethylene
TECHNICAL SPECIFICATIONS Pressure Stability 5 Bar Hydrostatic
Priming Volume 0.80 ml
Continuous flow rate at 300 mm Hg pressure 3 cc / hr
Activated flush rate at 300 mm Hg pressure 130 ml / min
PRODUCT CODE & PACK DETAILS GP/HM/03/XXX For detailed specifications & product codes, kindly refer table at the end of the catalogue

Specifications Parameter Value Units Notes
General Pressure Ranges – 30 to 300 mmHg –0.58 psi to 5.8 psi (-0.03 bar to 0.03 bar)
Overpressure 125 psi (x bar) minimum
Electrical @ 72°F (22°C) Unless Otherwise Stated Input Excitation 1 to 10 VDC Calibrated for 6 VDC
Dielectric Breakdown 10,000 VDC 5
Risk Current 2 µA Maximum (per AAMI), 5
Input Impedance 1800 to 3300  
Output Impedance 285 to 315 Ω  
Environmental Temperature Compensated 59° to 104° °F (15°C to 40°C)
Operating Storage 59°F to 104°F °F (15°C to 40°C)
–13° to 158° °F (–25°C to 70°C)
Humidity 10 to 90 %  
Light Sensitivity 1 mmHg maximum (per AMMI BP22)
Operating Product Life 168 hours  
Shelf Life 3 years  
Mechanical Weight < 0.0044 lb (<2 g)
Volume Displacement < 0.0008 in (<0.02 mm3)
Media Interface Medical grade, dielectric gel
Gel Tube Interface Material Polycarbonate

Performance Parameters * Units Minimum Type Maximum Notes
Offset mmHg – 25 0 25  
Sensitivity V / V / mmHg 4.95 5 5.05  
Calibration mmHg 97.50 100 102.50 2
Symmetry % ± 5  
Linearity(–30 to 100 mmHg) mmHg 1 6
Linearity (100 to 200 mmHg) % output 1 6
Linearity (200 to 300 mmHg) % output 1.50 6
Thermal Coefficient Offset mmHg / °C ± 0.30 3
Thermal Coefficient Span % / °C  ± 0.10 3
Frequency Response Hz 1200 5
Phase Shift degrees 5 5
Offset Drift mmHg/8hrs 1 4.50
  Download PDF